89 research outputs found

    A New SteatoScore in the Evaluation of Non-Alcoholic Liver Disease in Oncologic Patients

    Get PDF
    PurposeThe aims of this study were to evaluate the reproducibility of a new multi-parametric steatoscore (new SteatoScore) in oncologic patients with non-alcoholic fatty liver disease (NAFLD) and to compare it with computed tomography (CT). Materials and MethodsFifty-one (31 men, 20 women) oncologic patients, with a mean age and weight of 63.9 years and 78.33 kg, respectively, were retrospectively enrolled in the study. Patients underwent ultrasound (US) and computed tomography (CT) examinations as part of their oncologic follow-up protocol. US examinations were performed by using a 3.5-MHz convex probe. During the US examination, three standardized clips were obtained in each patient. Two operators performed all measurements, one of whom repeated the processing twice in 1 year. Hepatic/renal ratio (HR), attenuation rate (AR), diaphragm visualization (DV), hepatic/portal vein ratio (HPV), and portal vein wall visualization (PVW) were acquired and calculated by using Matlab and inserted in a multi-parametric algorithm called new SteatoScore. On unenhanced CT scan, hepatic attenuation (HA), liver-spleen difference (L-S), and liver/spleen ratio (L/S) were measured by placement of a region of interest (ROI) within liver and spleen parenchyma, avoiding areas with vessels and biliary ducts. ResultsThe intra-observer variability was greater than the inter-observer one, with intraclass correlation coefficient (ICC) values of 0.94 and 0.97, respectively. Correlation between single US and CT parameters provided an agreement in no case exceeding 50%. New SteatoScore showed high reproducibility, and high coefficient of correlation with L-S (R = -0.64; p < 0.0001) and L/S (R = -0.62; p < 0.0001) at CT. ConclusionNew SteatoScore has a high reproducibility and shows a good correlation with unenhanced CT in evaluation of oncologic patients with NAFLD

    Superlinear emission in bare perovskite: amplified spontaneous emission in disordered film versus single crystal lasing

    Get PDF
    Abstract We present an experimental study concerning the superlinear emission in organic-inorganic halide perovskites. Microphotoluminescence experiments under CW and picosecond excitation condition at low temperature and near field optical photoluminescence spectra at room temperature provide clear evidence of the very different origin of the superlinear regime in disordered films and microplates/microwires. Insights on the origin of modal structures of the emission spectra in the high excitation regime will be given by polarization-resolved photoluminescence experiments

    Human, All Too Human? An All-Around Appraisal of the “Artificial Intelligence Revolution” in Medical Imaging

    Get PDF
    Artificial intelligence (AI) has seen dramatic growth over the past decade, evolving from a niche super specialty computer application into a powerful tool which has revolutionized many areas of our professional and daily lives, and the potential of which seems to be still largely untapped. The field of medicine and medical imaging, as one of its various specialties, has gained considerable benefit from AI, including improved diagnostic accuracy and the possibility of predicting individual patient outcomes and options of more personalized treatment. It should be noted that this process can actively support the ongoing development of advanced, highly specific treatment strategies (e.g., target therapies for cancer patients) while enabling faster workflow and more efficient use of healthcare resources. The potential advantages of AI over conventional methods have made it attractive for physicians and other healthcare stakeholders, raising much interest in both the research and the industry communities. However, the fast development of AI has unveiled its potential for disrupting the work of healthcare professionals, spawning concerns among radiologists that, in the future, AI may outperform them, thus damaging their reputations or putting their jobs at risk. Furthermore, this development has raised relevant psychological, ethical, and medico-legal issues which need to be addressed for AI to be considered fully capable of patient management. The aim of this review is to provide a brief, hopefully exhaustive, overview of the state of the art of AI systems regarding medical imaging, with a special focus on how AI and the entire healthcare environment should be prepared to accomplish the goal of a more advanced human-centered world

    Structured reporting of computed tomography in the polytrauma patient assessment. A Delphi consensus proposal

    Get PDF
    Objectives: To develop a structured reporting (SR) template for whole-body CT examinations of polytrauma patients, based on the consensus of a panel of emergency radiology experts from the Italian Society of Medical and Interventional Radiology. Methods: A multi-round Delphi method was used to quantify inter-panelist agreement for all SR sections. Internal consistency for each section and quality analysis in terms of average inter-item correlation were evaluated by means of the Cronbach’s alpha (Cα) correlation coefficient. Results: The final SR form included 118 items (6 in the “Patient Clinical Data” section, 4 in the “Clinical Evaluation” section, 9 in the “Imaging Protocol” section, and 99 in the “Report” section). The experts’ overall mean score and sum of scores were 4.77 (range 1–5) and 257.56 (range 206–270) in the first Delphi round, and 4.96 (range 4–5) and 208.44 (range 200–210) in the second round, respectively. In the second Delphi round, the experts’ overall mean score was higher than in the first round, and standard deviation was lower (3.11 in the second round vs 19.71 in the first round), reflecting a higher expert agreement in the second round. Moreover, Cα was higher in the second round than in the first round (0.97 vs 0.87). Conclusions: Our SR template for whole-body CT examinations of polytrauma patients is based on a strong agreement among panel experts in emergency radiology and could improve communication between radiologists and the trauma team

    Teaching precision farming and entrepreneurship for European students: Sparkle online course

    Get PDF
    Within the framework of the European project named ‘SPARKLE’, an online course was created after studying educational needs on precision agriculture (PA), state of the art of technologies and a prospective study of the commercial sector. Five educational and research institutions, high-tech farms and enterprises specializing in technology transfer created the syllabus of the course and the platform contents. The course was designed to provide 30 h of student dedication, via online presentations, documents and videos for each topic. A free pilot course started in April 2020 and 385 students from Italy, Portugal, Greece & Spain enrolled. To trace performance and acquisition of competences, questionnaires were completed by students for each topic and a final overall test. Students’ opinions about the course were also registered using anonymous polls, and results evaluated, to be able to enhance the Sparkle course for subsequent editions. Students also took part in a business model competition, to solve real challenges proposed by farms, related to the use of these technologies

    Comparative expression pattern of Matrix-Metalloproteinases in human glioblastoma cell-lines and primary cultures

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Glioblastomas (GBM), the most frequent malignant brain tumors in adults, are characterized by an aggressive local growth pattern and highly invasive tumor cells. This invasion is facilitated by expression of matrix metalloproteinases (MMPs), a family of zinc-dependent endopeptidases. They mediate the degradation of protein components of the extracellular matrix. Twenty-three family members are known. Elevated levels of several of them have been reported in GBM. GBM cell-lines are used for <it>in vitro </it>studies of cell migration and invasion. Therefore, it is essential to know their MMP expression patterns. Only limited data for some of the cell-lines are published, yet. To fill the gaps in our knowledge would help to choose suitable model systems for analysis of regulation and function of MMPs during GBM tumorigenesis, cell migration and invasion.</p> <p>Findings</p> <p>We analysed MMP-1, -8, -9, -10, -11, -13, -17, -19, -20, -21, -23, -24, -26, -27, and MMP-28 expression in seven GBM cell-lines (SNB-19, GaMG, U251, U87, U373, U343, U138) and in four primary cell cultures by semiquantitative RT-PCR, followed changes in the MMP expression pattern with increasing passages of cell culture and examined the influence of TNF-α and TGF-ÎČ1 stimulation on the expression of selected MMPs in U251 and U373 cells.</p> <p>MMP-13, -17, -19 and -24 were expressed by all analyzed cell-lines, whereas MMP-20 and MMP-21 were not expressed by any of them. The other MMPs showed variable expression, which was dependent on passage number. Primary cells displayed a similar MMP-expression pattern as the cell-lines. In U251 and U373 cells expression of MMP-9 and MMP-19 was stimulated by TNF-α. MMP-1 mRNA expression was significantly increased in U373 cells, but not in U251 cells by this cytokine. Whereas TGF-ÎČ1 had no impact on MMP expression in U251 cells, it significantly induced MMP-11 and MMP-24 expression in U373 cells.</p> <p>Conclusions</p> <p>Literature-data and our own results suggest that the expression pattern of MMPs is highly variable, dependent on the cell-line and the cell-culture conditions used and that also regulation of MMP expression by cytokines is cell-line dependent. This is of high impact for the transfer of cell-culture experiments to clinical implementation.</p

    Diagnosis, monitoring and prevention of exposure-related non-communicable diseases in the living and working environment: DiMoPEx-project is designed to determine the impacts of environmental exposure on human health

    Full text link

    Iodine concentration and optimization in computed tomography angiography current issues

    No full text
    Computed tomography (CT) technology has seen a dramatic evolution in the recent past that has deeply changed the face of this diagnostic modality. Since the early days of helical single-slice and then multislice CT, CT angiography (CTA) has been one of the most technically demanding applications, both in terms of scanning technique and contrast medium (CM) injection protocol, due to the need to acquire a large amount of high-resolution data over a limited period corresponding to the peak contrast enhancement of the arterial system. Iodine concentration is one of the main determinants of arterial enhancement in CTA, and current low-osmolar and iso-osmolar nonionic CM for intravascular administration still come in a handful of molecules, but a relatively wide range of different iodine concentrations. This gives the opportunity to optimize CTA protocols as a function of several factors such as patient characteristics, CT technology, and CM features in an attempt to maximize the diagnostic yield of CTA examinations while considering patient safety and avoiding unnecessary extra costs. Our aim is to provide an up-To-date overview of the existing evidence on how changing iodine concentration can have an impact on CTA performance, especially with the use of state-of-The-Art CT and power injector technology, in the perspective of improving patient carewhileminimizing overall exposure to iodinated CM and ionizing radiation
    • 

    corecore